Measuring moisture when prepping the subfloor

HomeColumnMeasuring moisture when prepping the subfloor

moistureHas a customer ever called you complaining about hardwood floors cupping? Or about resilient floors having issues? If not, don’t let there be a first time!

Claims usually start with testing for moisture—not only in the flooring itself but also in the subfloor. In this article I’ll show you how to identify subfloor moisture issues and offer tips to prevent them.

Subfloor moisture issues can show up in many ways. Sometimes, they may be obvious—such as hardwood floors warping, cupping, or even buckling. And in other flooring types, you might notice other issues, such as delamination; adhesives that don’t hold; end-gapping; squeaks or unevenness; cracks in tiles; mold, mildew; or a musty smell.

Moisture can come from various sources. For one, the area around the building might have poor drainage, so groundwater moves into the subfloor. This is often connected with not having a vapor barrier—or a damaged one. Leaking pipes could also cause moisture to seep into the concrete. Additionally, environmental conditions can cause higher humidity levels. Thankfully, these issues are avoidable if you take some important measures before installing the floor.

Testing moisture in wood

If you have a subfloor made of plywood or OSB panels, the first step is to test for moisture levels. When installing solid or engineered hardwood flooring, the National Wood Flooring Association (NWFA) recommends checking 20 locations on the subfloor per 1,000 square feet. You can check this quickly using a pinless moisture meter.

The subfloor materials should be within 2%–4% moisture content of the floor. If they aren’t, allow them to acclimate until they’re within that range. On top of ensuring proper moisture levels, some installers put in an underlayment that helps retard moisture.

Maintain a consistent temperature and relative humidity in the installation area, and teach your clients to do the same. This way, you won’t have to worry about damage down the road.

Concrete moisture testing

Concrete slabs should have a vapor retarder underneath to prevent moisture from migrating into the concrete and eventually into the floor. Once you know the status of the vapor barrier, test the concrete moisture levels by using relative humidity testing approved by ASTM F2170. The standard generally requires floors to be under 75% relative humidity—although you should always follow the flooring manufacturer’s guidance. If the concrete still has excess moisture, allow it to dry in a consistent environment where dehumidifiers and HVAC systems are present.

These precautions will go a long way in avoiding issues. In turn, you’ll save yourself the time and money of repairs—and you’ll build your customers’ trust at the same time.


Jason Spangler is sales manager for Wagner Meters. He has more than 25 years’ experience in sales and sales management across a broad spectrum of industries. Spangler also has extensive industry involvement.

Must Read

Retailers React: What do you look for in a sales rep?

Every two weeks, FCNews seeks out flooring retailers across the country to offer their advice on hot topics of the day. This week, we...

Tarkett launches True to Form collection

Solon, Ohio—Tarkett has launched True to Form, a new collection on its premium Contour luxury vinyl tile. Combining the durability of Contour construction with...

J+J Flooring highlights new product at Design Days 2024

Chicago—J+J Flooring will be showcasing a variety of commercial flooring collections to the architecture and design community at its flagship showroom here during the...

Southwind names new territory managers

Dalton—Southwind has named Cindy Hansen the new north central territory manager and Kayla Kitten as the new south central territory manager. “We are pleased to...

Retailers, contractors step up to support FCEF

The significance of supporting the Floor Covering Education Foundation (FCEF) and raising awareness about skilled trade careers in the flooring industry has never been...

Laminate: State of the Industry 2024

Conventional wisdom would suggest that softening conditions in the new home construction market over the past eight to 10 months might put a damper...

As seen in

Sept. 11/18, 2023

DOWNLOAD
Some text some message..
X